Guide to Light Levels

Guide To Light Levels

Measuring light is a of pivotal importance when designing any project. Depending on the project, ‘Lux Levels’ will differ, typical examples of Lux Levels can be found here. The following chart suggests general light levels and is for preliminary guidance only. For specific applications, please check the relevant standards and recommendations or contact Veelite.

As a base guideline, a full Moon will provide a maximum of 1 Lux light level, but usually much less.

Moonlight

External Light Levels

External ApplicationClass/LevelLight Level
Canopied Areas–150 Lux
Facade Floodlight (Note 1)–50-1500 Lux

Notes:
1) Depends on Local light levels & surface of buildings.
2) Vehicular & Pedestrian Traffic.

Car ParksClass/LevelLight Level
High Traffic Areas–20 Lux
Medium Traffic Areas–10 Lux
Low Traffic Areas–5 Lux
Roadways (Note 2)Class/LevelLight Level
City Centre–30 Lux
Suburban–20 Lux
Village–15 Lux
Sports:Class/LevelLight Level
Football/RugbyNational/Intn500 Lux
–Regional/Local 200 Lux
–Local/Training75 Lux
TennisNational/Intn500 Lux
–Regional/Local 300 Lux
–Local/Training200 Lux
EquestrianNational/Intn500 Lux
–Regional/Local 200 Lux
–Local/Training100 Lux

Notes:
CIBSE:  Local is approx Category 111, Regional is approx Category 11 and National/Intn is approx Category 1.

Internal Light Levels

Retail Store HighBays
Internal ApplicationClass/LevelLight Level
General Industry (Note 1)–300 Lux
Retail Stores–500 Lux
Supermarkets–750 Lux
School Assembly Halls–300 Lux
Entrances/Exits/Canteens–200 Lux
Restrooms–150 Lux
Corridor Area/Toilets–100 Lux
Warehouse Lighting
Internal Carpark Lights
Swimming Pool Lighting
Ware
houses
Class/LevelLight Level
Working/Packaging/Dispatch–300 Lux
Small Item Storage–300 Lux
Reading Necessary/No small items–200 Lux
Search only–100 Lux
Offices–500 Lux
Counter Areas–500 Lux
Filing/Print Rooms–300 Lux
Car ParksClass/LevelLight Level
Parking Bays & Driving Lanes–75 Lux
Entrances & Exits–250-300 Lux

Notes:
1) Varies from 300 Lux to 1500 Lux depending on the nature of the work.
2) Light Levels in different areas must also be in relation to each other to avoid
contrasts.

Restaurants
& Hotels
Class/LevelLight Level
Food Preparation & Cooking–500 Lux
Wash up/Vegetable Preparation–300 Lux
Food Storage Areas/Cellars–150 Lux
Bedrooms–50-100 Lux
Bars/Dining Rooms–50-200 Lux
SportsClass/LevelLight Level
BadmintonNational/Itnl750 Lux
–Regional/Local500 Lux
–Local/Training300 Lux
SwimmingNational/Itnl750 Lux
–Regional/Local500 Lux
–Local/Training200 Lux

Notes:
CIBSE:  Local is approx Category 111, Regional is approx Category 11 and National/Intn is approx Category 1.

SEARCH PROJECTS

QUICK INTRO TO VEELITE
Quick Introduction to VeeLite
© 2026 | Copyright VeeLite